Smart Rack
1Compute, UPS power, precision cooling, and monitoring integrated into a single 42U cabinet. A complete edge or micro data center, deployable anywhere.
Smart Rack & Aisle Containment
One partner for IT infrastructure: an all-in-one Smart Rack for the edge, sealed aisle containment for the hall, and IoT monitoring across both.
The system, end to end
Smart Rack puts a whole micro data center in a single cabinet. Aisle containment scales it across the hall. IoT monitoring watches both in real time.
Compute, UPS power, precision cooling, and monitoring integrated into a single 42U cabinet. A complete edge or micro data center, deployable anywhere.
Sealed hot and cold separation that holds cooling at the rack face and grows row by row as the hall fills. The technical core of the cooling story.
Touchscreen HMI and DCIM telemetry surface power, temperature, and environment live, with threshold alerting across every rack and aisle.
Pillar 1 / the edge
The GSPE Smart Rack folds compute, UPS power, precision cooling, and intelligent monitoring into a single 42U enclosure. Roll it into a branch, a factory floor, or a remote site and the room becomes a data center.
Pillar 2 / the hall
Left, an open aisle: cold supply and hot exhaust meet in the room, bypass air never does work, recirculated exhaust drives inlet temperatures up, and hot spots form. Right, a sealed barrier holds cold supply in front of the racks and captures exhaust behind it.
What seals the aisle
Every component is fabricated to fit your rack height and row length, then assembled into the rooms you already run.
Solid aluminium or clear polycarbonate close the top of the aisle. Clear panels keep light and CCTV sightlines through the hall while still sealing the contained volume.
Sliding or swing end doors with self-closing hinges and viewing panels seal the aisle ends and stay shut on their own.
Snap-in panels seal every empty rack U so air cannot short-circuit through the rack face. The cheapest fix for inlet recirculation.
Brush-sealed cable cutouts and floor seals close the gaps where cabling and frames meet the raised floor and slab.
Filler baffles bridge mismatched rack heights and the gaps at row ends, so the contained volume stays fully sealed.
Fusible-link, gravity-release roof panels drop clear on a fire signal, so containment never blocks sprinkler discharge.
Both stop the mixing. The right choice depends on your room, your CRAC layout, and how dense the racks get.
Seal the cold aisle into a corridor. The rest of the room becomes the hot return. Simplest retrofit on a raised-floor hall.
Best when you are retrofitting an existing raised-floor room and want the fastest win.
Seal the hot aisle and duct exhaust to a ceiling plenum. The whole room becomes cool supply, so operators work in comfortable space.
Best when new build or high-density halls of 15 kW per rack and up with a ceiling return plenum.
Once the air stops mixing you can raise supply temperature into the ASHRAE allowable band and let the cooling plant coast.
Pillar 3 / over both
A touchscreen HMI and DCIM telemetry read power, temperature, and environment in real time across smart racks and contained aisles, with threshold alerting before a hot spot ever forms.
GSPE DCIM dashboard. Live metrics, ranges, and alert thresholds are configured to your facility during commissioning.
Scalable IT infrastructure
The same line covers a single edge cabinet, a contained row, and a modular facility, so the architecture grows with the load instead of being torn out and replaced.
A complete, self-contained edge data center: integrated UPS, precision cooling, intelligent monitoring, access control, and predictive environmental alerting in one cabinet.
Aisle containment physically separates cold supply from hot exhaust, eliminating bypass airflow and lowering both PUE and mechanical cooling OPEX as the room fills.
Deploy a complete, self-sufficient IT environment anywhere, with integrated cooling, power, and security for edge computing or rapid site scaling.
Materials and fire compliance
Containment must never compromise life safety. Panels seal tight in normal operation and open fully when the fire system calls for it.
Extruded aluminium structure, corrosion-free, light, and re-configurable as the row layout changes.
Impact-resistant clear polycarbonate keeps light and sightlines through the hall, with a UL94 flame-retardant rating.
Heat-triggered links release roof panels by gravity, so containment cannot obstruct sprinkler or gas suppression.
Panel layout keeps VESDA sampling and sprinkler coverage effective inside the contained volume.
Live DCIM
Every smart rack and contained aisle reports to one dashboard, made to measure for your facility and live from commissioning. Power, thermal, environment, and access on a single pane, installed around a running hall with no shutdown.




We size a smart rack for the edge, design containment to fit your hall, wire up IoT monitoring across both, and install around a live room.